Minnesota Department of Transportation

511 Travel Info

Approved/Qualified Products

Longitudinal Barriers Products

New and full-replacement installations must use MASH-compliant systems.

MASH High-Tension Cable Barrier

Proprietary MASH high-tension cable barrier (HTCB) systems are engineered systems subject to MnDOT’s Approved/Qualified Products Policy.

Product Manufacturer Approval Date Notes
MASH 2016 Cable System Gibraltar Global March 17, 2025 Approved for 1V:4H or flatter cross slope.
O-Post 4 Rope System Brifen USA March 17, 2025 Approved for 1V:6H or flatter median slope and 1V:4H or flatter outside roadside slope.

Qualified Foundation Designs for MASH HTCB

MASH HTCB systems must employ qualified anchor, terminal post, and line post foundation desfoundation designs may be available from the manufacturer but require qualification before use.

Name* Compatible System(s) Foundation Type Qualification Date Minimum Soil Properties Other Restrictions, if Applicable
11′-6″ Anchor Block

Gibraltar

MASH 2016 Cable System

Anchor 10/15/2025

Cohesive Soils:
C ≥ 1000 psf
γ ≥ 110 pcf

Depth to normal water table ≥ 5′
N/A
TP4-1 Terminal Post Footing Gibraltar MASH 2016 Cable System Terminal Post 10/15/2025

Cohesive Soils:
C ≥ 1000 psf
γ ≥ 110 pcf

Depth to normal water table ≥ 5′
N/A
TP4-4 Line Post Footing Gibraltar MASH 2016 Cable System Line Post 10/15/2025

Cohesive soils:
C ≥ 1000 psf
γ ≥ 110 pcf
Depth to normal water table ≥ 6′

OR

Noncohesive soils:
ɸ ≥ 30°
γ ≥ 110 pcf

Depth to normal water table ≥ 6′
N/A
Example System Name(s) Line post, terminal post, or anchor   Shear strength and unit weight of cohesive soil; friction angle and unit weight of noncohesive soil; minimum depth to normal water table; maximum assumed frost depth. E.g. if minimum radius for 10-foot spacing differs from 250 ft.

* See links for drawings and specifications.

NCHRP 350 High-Tension Cable Barrier

NCHRP 350 systems are available only for maintenance, partial reassembly of existing barriers, or projects let prior to March 17, 2025.

Product Manufacturer Approval Date
Brifen TL-4 (4-Rope) WRSF Brifen 8/22/2012
Gibraltar TL-4-4-Cable Barrier System Gibraltar 8/22/2012

Composite/Plastic Block-outs **

Manufacturer FHWA Eligibility Letter
8” Block Depth
NCHRP 350 ***
FHWA Eligibility Letter
8” Block Depth
MASH
FHWA Eligibility Letter
12” Block Depth
MASH
Approval Date
Mondo Polymer Technologies B-39B B-39D
B-278A
B-39C 10/11/2019
Valtir, LLC B-85E - - 11/9/2016
Valtir, LLC - B-342 B-353 12/23/2021

** Installer shall assume all responsibility for proper application and adherence to the manufacturer's installation instructions.

***Product may be used on in-place NCHRP 350 systems requiring replacement or maintenance.  

igns compatible with the HTCB system and site-specific soil information from the Soils Data Report. See the Guidance section of this page for the Qualification Requirements for MASH HTCB Foundations. Foundation designs that have already been evaluated as meeting the qualification requirements are listed in the Qualified Foundation Designs table, below. Additional