"ExPipeandInsp ", Dictionary, "Existig Pipe and Inspection Record Type" "ExPipeandInsp", point, "Exist HYDINFRA Pipe and Inspection", 5, seconds, 1, Code "HYDINFRA ID", numeric, 0, 0, 1e+010, 0, normal, "Only use HYDINFRA ID from database", normal, Label1 "Local ID", text, 30, normal, "Temporary field identifier", normal, Label2 "Activity", menu, required, "Describes Activity", required "Liner" "Extension" "Abandon" "Change" "Material", menu, required, "Material of liner, extension or change.", required "Concrete", default "Corg. Mtl (CMP)" "Corg. Steel (CSP)" "Corg. Aluminum (CAP)" "Structural Plate" "Corrugated Plastic" "Smooth Plastic" "Liner Cured in Place" "Liner Plastic" "Other" "Width Qt.", numeric, 0, 1, 30480, 24, required, "Measure width of liner, extension or", required "Height Qt.", numeric, 0, 1, 30480, 24, required, "Measure ht of liner, extension or change", required "Dim. Units", menu, required, "Dimension Units", required "Inches", default "Shape", menu, required, "Cross-sectional shape of pipe interior", required "Arch" "Box" "Round", default "Other" "Elliptical" "Length", numeric, 0, 0, 1000, 0, required, "length of liner or extension or pipe ", required "Lgth Units", menu, required, "Length Units", required "Feet", default "Lngth Deter. Method", menu, required, "How was length determined?", required "Measured" "Estimated", default "Scaled" "Class", menu, normal, "Pipe Class or Gage", normal "8 Gage" "10 Gage" "12 Gage" "14 Gage" "16 Gage" "18 Gage" "Class II" "Class III" "Class IV" "Class V" "Special Design" "Unknown", default "Visible Length", menu, required, "Can you see entire length of pipe?", required "Complete Visual" "Partial Visual", default "Visible Circum ", menu, required, "Can you see entire circumference of pipe", required "Complete Visual" "Partial Visual", default "Overall Condition", menu, required, "Structural integrity of pipe. 0=unknown", required "1" "2" "3" "4" "0" "Clean?", menu, normal, "Pipe's end is 1/3 full of sediment.", normal "Y" "N" "Repair?", menu, normal, "Pipe needs to be fixed -- rate 3 or 4.", normal "Y" "N" "Standing Water?", menu, normal, "Is water standing or backed up in pipe?", normal "Y" "N" "Silt present?", menu, normal, "Sediment deposited in pipe.", normal "Y" "N" "Plugged?", menu, normal, "Pipe end is mostly obstructed.", normal "Y" "N" "Pitting/Rusting?", menu, normal, "Piped is pitted or rusted", normal "Y" "N" "Spalling/Flaking?", menu, normal, "Conc 1/4" spalls/CMP loose flakes", normal "Y" "N" "Cracks?", menu, normal, "Pipe has cracks", normal "Y" "N" "Holes?", menu, normal, "Hole goes through the pipe", normal "Y" "N" "Joints Separated?", menu, normal, "Joint is separated more than 1"", normal "Y" "N" "Misalignment?", menu, normal, "Pipe section offset laterally, has gap", normal "Y" "N" "Deformed Pipe?", menu, normal, "Pipe Distress - Pipe shape is distorted", normal "Y" "N" "Infiltration?", menu, normal, "Soil or water infiltration into pipe", normal "Y" "N" "Piping?", menu, normal, "Water runs along pipe exterior", normal "Y" "N" "Inslope Cavitation?", menu, normal, "Holes in inslope around pipe", normal "Y" "N" "Road Distress?", menu, normal, "Road bump, dip, pvmt patch or cracks", normal "Y" "N" "Void in Road?", menu, normal, "Evidence of hole in road near pipe", normal "Y" "N" "Repair under Road?", menu, normal, "Is repair required inside shoulder PI?", normal "Y" "N" "Erosion?", menu, normal, "Erosion near pipe.", normal "Y" "N" "Marker Type?", menu, normal, normal "None", default "Guardpost" "Sign" "ID Post" "ID Tag" "Comment", text, 100, normal, "Comment on extraordinary circumstances", normal